Application Procedure Part 6




 CLASSIC Cooling treatment on ROOF Area:-
To overcome HEAT problem steps involved in the treatment are-

    1.   Clean roof surface (surface has to be free from loose dust, oil, grease, bitumen & algae.)Clean the surface using Wire brush/ Nylon Brush/Scrapper & Water.

    2.   Wash the surface thoroughly with water using pressure pumps.

   3.   Apply 1 coat uniform layer of COOL GUARD Solution with brush/ Roller on substrate.

      4.   After duration of drying of 1-2 hrs apply 2nd coat of COOL GUARD with brush/ Roller/ spray.

5.   After 3-4 hrs apply 1 coat of TRANSEAL.


6.   For full curing let the coating dry for 12 hrs.

Note: -Before application of every layer, the substrate should be clean & dust free.

Preparation of Cool Guard Solution on the site. 
·         Take 700 ml water in bucket.
·          Add powder of cool guard to the water along with stirring and make a viscous paste like emulsion.
·         Add more water up to 500 ml to the above viscous emulsion with regular stirring to make brushable emulsion.
·         Apply the coating on the clean substrate.
·         Prepared cool guard solution can be used till 2 hrs after mixing.
·         Prepared solutions should not be kept uncovered, when not in use.


_____________________________________


Application Procedure For Ext Wall Coating:-

  To overcome HEAT problem steps involved in the treatment are-

1.   Clean the surface (surface has to be free from loose dust, oil, grease, bitumen, Corrosion & algae.) Clean the surface using Wire brush/ Nylon Brush/Scrapper & Water.

2.   Apply uniform layer of primer with brush/ Roller/ spray on substrate.

3.   After duration of drying of 4-5 hrs apply 2 coats of MX COOL WRAP PREMIUM with brush/ Roller/ spray in between duration of 4-5 hours.

4.   For full curing let the coating dry for 12 hrs.

____________________________________

Thursday, 4 December 2014

Application Procedure Part 4



Application Procedure for Anti Corrosions
Description :-  

Mx Rustop is a blend of complex inorganic and organic chemicals to work as rust remover and preventer. The product converts existing rust into protective complex on an iron, steel or any metal (copper, aluminum, brass or the like) surface. Mx Rust EP is a Anti Rust Protective coating used in the industry to protect metal from severe adverse conditions including corrosion

Application Procedure:-
1. Clean the surface (surface has to be free from dust, oil Paints, grease & algae.) 
2. Apply uniform layer of Mx Rustop (Rust remover) with the help of cotton, Soft Cloth or by dipping, brushing or spraying on the surface (Also apply where the joint is & overlapping is found).
3.  After that before dry, rub the surface with cotton and remove the rust.
4. After interval of 24 hrs – apply LAC-RT (At 3-4 hrs intervals, depend upon atmosphere & Surface) with the help of Spray gun.

5.  After duration of drying of 12 hrs apply 1 coat of Mx Rust EP with brush & spray.

6. After Drying 1 coat, apply 2 coat of Mx Rust EP.





Application Procedure: For Paint on New Metal Sheet

1.   Clean the surface with cloth.

2.   Apply uniform layer of Rustop on the metal surface.

3.   Scrub and clean the rustop (when it is wet) surface with cloth.

4.   After complete drying of surface,
 apply black metal paint.

Application Procedure: For Paint 
on Old Metal Sheet (Maximum Rust)
1.   Clean the surface with cloth.

2.   Apply uniform layer of Rustop
 on the metal surface.

3.   Scrub and clean the rustop
 (when it is wet) surface with cloth/
 scotch bite.

4.   After complete drying of surface, 
apply rustop plus and then after scrub
 and clean the surface with cloth and 
scotch bite.

5.   At last after complete drying of 
metal surface, apply black paint.