Saturday 13 December 2014

Application Procedure Part 6




 CLASSIC Cooling treatment on ROOF Area:-
To overcome HEAT problem steps involved in the treatment are-

    1.   Clean roof surface (surface has to be free from loose dust, oil, grease, bitumen & algae.)Clean the surface using Wire brush/ Nylon Brush/Scrapper & Water.

    2.   Wash the surface thoroughly with water using pressure pumps.

   3.   Apply 1 coat uniform layer of COOL GUARD Solution with brush/ Roller on substrate.

      4.   After duration of drying of 1-2 hrs apply 2nd coat of COOL GUARD with brush/ Roller/ spray.

5.   After 3-4 hrs apply 1 coat of TRANSEAL.


6.   For full curing let the coating dry for 12 hrs.

Note: -Before application of every layer, the substrate should be clean & dust free.

Preparation of Cool Guard Solution on the site. 
·         Take 700 ml water in bucket.
·          Add powder of cool guard to the water along with stirring and make a viscous paste like emulsion.
·         Add more water up to 500 ml to the above viscous emulsion with regular stirring to make brushable emulsion.
·         Apply the coating on the clean substrate.
·         Prepared cool guard solution can be used till 2 hrs after mixing.
·         Prepared solutions should not be kept uncovered, when not in use.


_____________________________________


Application Procedure For Ext Wall Coating:-

  To overcome HEAT problem steps involved in the treatment are-

1.   Clean the surface (surface has to be free from loose dust, oil, grease, bitumen, Corrosion & algae.) Clean the surface using Wire brush/ Nylon Brush/Scrapper & Water.

2.   Apply uniform layer of primer with brush/ Roller/ spray on substrate.

3.   After duration of drying of 4-5 hrs apply 2 coats of MX COOL WRAP PREMIUM with brush/ Roller/ spray in between duration of 4-5 hours.

4.   For full curing let the coating dry for 12 hrs.

____________________________________

1 comment: